Inspection Procedure
- INSPECT FUSES (P/l, AM2, IG2, EFI MAIN, IGN)
- Remove the P/l fuse, AM2 fuse, IG2 fuse and EFI MAIN fuse from the engine room No. 1 relay block.
- Remove the IGN fuse from the instrument panel junction block.
- Measure the resistance of the fuses.
Standard resistance:
Below 1 Ω
- Reinstall the fuses.
NG: CHECK FOR SHORT IN ALL HARNESSES AND CONNECTORS CONNECTED TO FUSE AND REPLACE FUSE
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
OK: GO to next step
- INSPECT RELAY (IG2, EFI MAIN)
- Remove the integration relay and IG2 relay from the engine room No. 1 relay block.
- Measure the resistance between the terminal of the integration relay.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions 1C-1 - 1A-4 10 kΩ or higher Below 1 Ω (When battery voltage is applied to terminals 1A-2 and 1A-3) - Measure the resistance between the terminal of the IG2 relay.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions 3-5 10 kΩ or higher Below 1 Ω (When battery voltage Is applied to terminals 1 and 2) - Reinstall the relay.
NG: REPLACE RELAY
OK: GO to next step
- CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)
- Disconnect the B30 ECM connector.
- Measure the resistance.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITIONTester Connection Specified Condition B30-104 (E1) - Body ground Below 1 Ω - Reconnect the ECM connector.
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
OK: GO to next step
- INSPECT ECM (IGSW VOLTAGE)
- Disconnect the B30 and A9 ECM connectors.
- Turn the ignition switch ON.
- Measure the voltage between the terminals of the B30 and A9 ECM connectors.
Standard voltage
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions A9-28 (IGSW) - B30-104 (E1) 9 to 14 V - Reconnect the ECM connector.
OK: REPLACE ECM
NG: GO to next step
- CHECK HARNESS AND CONNECTOR (RELAY BLOCK - ECM, IGNITION SWITCH, BATTERY)
- Disconnect the A9 ECM connector.
- Disconnect the E3 ignition switch connector.
- Disconnect the battery positive terminal.
- Remove the AM2 fuse and IG2 relay.
- Measure the resistance between the terminals.
Standard resistance (Check for open)
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions A9-28 (IGSW) - Engine room No. 1 relay block IG2 relay terminal 5 Below 1 Ω Engine room No. 1 relay block IG2 relay terminal 2 - Body ground Below 1 Ω Positive (+) battery cable - Engine room relay block No. 1 AM2 fuse terminal 1 Below 1 Ω Positive (+) battery cable - Engine room relay block No. 1 IG2 relay terminal 3 Below 1 Ω E3-7 (AM2) - Engine room No. 1 relay block AM2 fuse terminal 2 Below 1 Ω E3-6 (IG2) - Engine room No. 1 relay block IG2 relay terminal 1 Below 1 Ω Standard resistance (Check for short)
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions A9-28 (IGSW) or Engine room No. 1 relay block IG2 relay terminal S-Body ground 10 kΩ or higher Positive (+) battery cable or Engine room No. 1 relay block AM2 fuse terminal 1 - Body ground 10 kΩ or higher Positive (+) battery cable or Engine room No. 1 relay block IG2 relay terminal 3 - Body ground 10 kΩ or higher E3-7 (AM2) or Engine room No. 1 relay block AM2 fuse terminal 2 -Body ground 10 kΩ or higher E3-6 (IG2) or Engine room No. 1 relay block IG2 relay terminal 1 - Body ground 10 kΩ or higher - Reinstall the relay and fuse.
- Reconnect the connectors.
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: GO to next step
- INSPECT IGNITION SWITCH
(see
INSPECTION PROCEDURE )
NG: REPLACE IGNITION SWITCH
OK: GO to next step
- CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - ECM, BATTERY, BODY GROUND)
- Disconnect the A9 ECM connector.
- Remove the integration relay from the engine room No. 1 relay block.
- Disconnect the integration relay connector.
- Remove the P/l fuse from the engine room No. 1 relay block.
- Check the resistance between the terminals.
Standard resistance (Check for open)
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions A9-2 (+B) - 1A-4 Below 1 Ω A9-1 (+B2) - 1A-4 Below 1 Ω A9-44 (MREL) - 1A-2 Below 1 Ω Engine room relay block No. 1 P/l fuse terminal 2 - 1C-1 Below 1 Ω 1A-3 - Body ground Below 1 Ω Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard resistance (Check for short)
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions A9-2 (+B) or 1A-4 - Body ground 10 kΩ or higher A9-1 (+B2) or 1A-4 - Body ground 10 kΩ or higher A9-44 (MREL) or 1A-2 - Body ground 10 kΩ or higher Engine room No. 1 relay block P/I fuse terminal 2 or 1C-1 - Body ground 10 kΩ or higher - Reconnect the connectors.
- Reinstall the integration relay and P/l fuse.
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: REPAIR OR REPLACE ENGINE ROOM NO. 1 RELAY BLOCK