Inspection Procedure
- CHECK POWER WINDOW LOCK SWITCH
- Push the window lock switch OFF (normal) and check that the remote UP/DOWN function operates.
OK: END
NG: Go to next step.
- CHECK MANUAL UP/DOWN FUNCTION
- Check that the passenger side door window and slide door windows can be operated via each regulator switch.
NG: OTHER PROBLEM
OK: Go to next step.
- INSPECT POWER WINDOW MASTER SWITCH
HINT:
Inspect the switch with the nonoperational remote function.
- Remove the master switch.
- Check the resistance between the terminals of the master switch when each switch is operated, as shown in the table below.
Standard resistance: Passenger side switch
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
RESISTANCE SPECIFICATIONWindow Lock Switch Power Window Switch Terminal No. Specified Condition OFF (Normal) UP 1 - 15, 6 - 13 Below 1 Ω OFF 1 - 13 - 15 DOWN 1 - 13, 6 - 15 ON (Lock) UP 6 - 13 OFF 13 - 15 DOWN 6 - 15 Rear LH switch
RESISTANCE SPECIFICATIONWindow Lock Switch Power Window Switch Terminal No. Specified Condition OFF (Normal) UP 1 - 10, 6 - 12 Below 1 Ω OFF 1 - 10 - 12 DOWN 1 - 12, 6 - 10 ON (Lock) UP 6 - 12 OFF 10 - 12 DOWN 6 - 10 Rear RH switch
RESISTANCE SPECIFICATIONWindow Lock Switch Power Window Switch Terminal No. Specified Condition OFF (Normal) UP 1 - 16, 6 - 18 Below 1 Ω OFF 1 - 16 - 18 DOWN 1 - 18, 6 - 16 ON (Lock) UP 6 - 18 OFF 16 - 18 DOWN 6 - 16
NG: REPLACE POWER WINDOW MASTER SWITCH
OK: REPAIR OR REPLACE HARNESS AND CONNECTOR (MASTER SWITCH - EACH REGULATOR SWITCH)