Service Data
VSC OFF Switch
VSC OFF SWITCH - SERVICE DATA
| Item | Tester Connection | Switch Condition | Specified Condition |
|---|---|---|---|
| VSC OFF switch | 3 - 6 | Pressed | Below 1 Ω |
| Not pressed | 10 kΩ or higher |
Stop Light Control Switch
STOP LIGHT CONTROL SWITCH - SERVICE DATA
| Item | Tester Connection | Switch Condition | Specified Condition |
|---|---|---|---|
| Stop light control relay | 3 - 4 | When battery voltage is applied to terminals 1 and 2 | 10 kΩ or higher |
| When battery voltage is not applied to terminals 1 and 2 | Below 1 Ω | ||
| 3 - 5 | When battery voltage is not applied to terminals 1 and 2 | 10 kΩ or higher | |
| When battery voltage is applied to terminals 1 and 2 | Below 1 Omega; |