Camshaft Timing Oil Control Valve Assembly: Inspection
- INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY
- Check the resistance.
- Measure the resistance between the terminals.
Standard resistance: 6.9 to 7.9 Ω at 20°C (68°F)
If the result is not as specified, replace the oil control valve assembly.
- Measure the resistance between the terminals.
- Check the operation.
- Connect the positive (+) battery lead to terminal 1 and the negative (-) lead to terminal 2, and check the movement of the valve.
Standard
VALVE MOVEMENT SPECIFIED CONDITIONCondition Specified Condition Battery positive (+) voltage applied Valve moves to the left Battery positive (+) voltage cut off Valve moves to the right Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
If the result is not as specified, replace the oil control valve.
NOTE: If the valve does not return properly because of foreign matter intrusion, a small amount of leakage in the advanced direction may occur and a DTC may be output.
- Connect the positive (+) battery lead to terminal 1 and the negative (-) lead to terminal 2, and check the movement of the valve.
- Check the resistance.