Service Data
AIR CONDITIONING - SERVICE DATA
| Refrigerant charge volume | 330 to 390 g (11.64 to 13.76 oz.) |
|---|---|
| PTC heater assembly | 1 - 2: Below 1 ohms 2 - 3: Below 1 ohms 1 - 3: Below 1 ohms |
| Blower resistor | 1 - 4: 3.12 to 3.60 ohms 3 - 4: 1.45 to 1.67 ohms 2 - 4: 0.52 to 0.60 ohms |
| Compressor and pulley | 10.1 to 11.1 ohms at 25°C (77°F) |
| Heater blower motor relay | 3 - 4: Below 1 ohms 3 - 4: 10k ohms or higher (Apply battery voltage to terminals 1 and 2) 3 - 5: 10k ohms or higher 3 - 5: Below 1 ohms (Apply battery voltage to terminals 1 and 2) |
| PTC heater relay | 3 - 5: 10k ohms or higher 3 - 5: Below 1 ohms (Apply battery voltage to terminals 1 and 2) |
for Manual transaxle
AIR CONDITIONING - SERVICE DATA (FOR MANUAL TRANSAXLE)
| Idling speed Switch A/C OFF |
550 to 650 rpm |
| Idling speed Switch A/C ON (A/C Lo --> Hi) |
700 --> 850 rpm |
for Automatic transaxle
AIR CONDITIONING - SERVICE DATA (FOR AUTOMATIC TRANSAXLE)
| Idling speed Switch A/C OFF |
650 to 750 rpm |
| Idling speed Switch A/C ON (A/C Lo --> Hi) |
700 --> 850 rpm |