Inspection Procedure
- INSPECT FUSE (POWER)
- Remove the fuse from the instrument panel J/B assembly.
- Check the continuity.
Standard:
Continuity
NG: REPLACE FUSE
OK: Go To Next Step
- INSPECT INSTRUMENT PANEL J/B ASSEMBLY
- Remove the power window relay.
- Turn the ignition switch ON.
- Check the voltage between the J/B terminals 1 and 2.
Standard:
10 to 14 V
NG: REPLACE INSTRUMENT PANEL J/B ASSEMBLY
OK: Go To Next Step
- INSPECT POWER WINDOW RELAY (POWER)
- Remove the relay from the backside of the instrument panel J/B assembly.
- Check the continuity.
- Check the voltage between the J/B terminals 1 and 2.
Standard
SPECIFIED CONDITIONTerminal No. Condition Specified Condition 1-2 Constant Continuity 3-5 Apply battery voltage to terminal 1 and 2 Continuity
NG: REPLACE POWER WINDOW RELAY
OK: Go To Next Step
- CHECK WIRE HARNESS (TERMINAL B2, BW OR E)
- Disconnect the D17 switch connector.
- Check the voltage or continuity between each terminal of the wire harness side connector and the body ground.
Standard
SPECIFIED CONDITIONSymbols (Terminal No.) Condition Specified Condition B2 (D17-11) - Body ground Ignition ON 10 to 14 V BW (D17-7) - Body ground Constant 10 to 14 V E (D17-1) - Body ground Constant Continuity
NG: REPAIR OR REPLACE HARNESS AND CONNECTOR
OK: Go To Next Step
- CHECK WIRE HARNESS (TERMINAL B)
- Turn the ignition switch ON.
- Check the voltage between terminal 6 of the wire harness side connector and the body ground.
Standard
SPECIFIED CONDITIONTerminal No. Condition Specified Condition B (D17-6) - Body ground Ignition switch ON 10 to 14 V
NG: REPAIR OR REPLACE HARNESS AND CONNECTOR (POWER WINDOW RELAY MASTER SWITCH)
OK: REPLACE POWER WINDOW MASTER SWITCH ASSEMBLY