Knock Sensor: Inspection
- INSPECT KNOCK SENSOR
- Check the resistance.
- Using an ohmmeter, measure the resistance between the terminals.
Standard resistance
STANDARD RESISTANCE
| Tester Connection |
Specified Condition |
| 1 (Ground) - 2 (Output) |
120 to 180 kΩ at 20°C (68°F) |
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
If the result is not as specified, replace the knock sensor.