Service Data
SERVICE DATA REFERENCE CHART
| Inverter | A-2 (GIVA) - A-16 (GINV) | HV Approximately 0 V |
| A-3 (GIVB) - A-16 (GINV) | Approximately 0 V | |
| A-4 (GUU) - A-16 (GINV) | Approximately 14 to 16 V | |
| A-5 (GVU) - A-16 (GINV) | Approximately 14 to 16 V | |
| A-6 (GWU) - A-16 (GINV) | Approximately 14 to 16 V | |
| A-7 (MIVA) - A-16 (GINV) | Approximately 0 V | |
| A-8 (MIVB) - A-16 (GINV) | Approximately 0 V | |
| A-9 (MUU) - A-16 (GINV) | Approximately 14 to 16 V | |
| A-10 (MVU) - A-16 (GINV) | Approximately 14 to 16 V | |
| A-11 (MWU) - A-16 (GINV) | Approximately 14 to 16 V | |
| A-12 (VH) - A-16 (GINV) | Approximately 0.5 V | |
| A-13 (CPWM) - A-32 (GCNV) | Approximately 0 V | |
| A-14 (GSDN) - A-32 (GCNV) | Approximately 2 to 4.5 V | |
| A-15 (VL) - A-32 (GCNV) | Approximately 0.5 V | |
| A-16 (GINV)-C-2 (GND) | Approximately 0 V | |
| A-18 (GIWA) - A-16 (GINV) | Approximately 0 V | |
| A-19 (GIWB) - A-16 (GINV) | Approximately 0 V | |
| A-20 (CT) - A-16 (GINV) | Approximately 0 V | |
| A-21 (GIVT) - A-16 (GINV) | Approximately 2 to 4.5 V | |
| A-22 (GFIV) - A-16 (GINV) | Approximately 5 to 8 V | |
| A-23 (MIWA) - A-16 (GINV) | Approximately 0 V | |
| A-24 (MIWB) - A-16 (GINV) | Approximately 0 V | |
| A-25 (MSDN) - A-16 (GINV) | Approximately 0 V | |
| A-26 (MIVT) - A-16 (GINV) | Approximately 2 to 4.5 V | |
| A-27 (MFIV) - A-16 (GINV) | Approximately 5 to 8 V | |
| A-28 (OVH) - A-16 (GINV) | Approximately 5 to 8 V | |
| A-29 (CSDN) - A-32 (GCNV) | Approximately 0 V | |
| A-30 (FCV) - A-32 (GCNV) | Approximately 13.5 to 16.5 V | |
| A-31 (OVL) - A-32 (GCNV) | Approximately 13.5 to 16.5 V | |
| A-32 (GCNV) - C-2 (GND) | Approximately 0 V | |
| B-1 (ILK) - Body ground After installing the probe to the terminal, temporarily install the inverter cover. It does not have to be tightened with the bolts at this point. | Below 1 Ω | |
| C-1 (IGCT) - C-2 (GND) | Approximately 8 to 16 V | |
| C-2 (GND) - Body ground | Below 1 Ω | |
| Converter operation | Auxiliary battery voltage : READY light ON | 14 V |
| Auxiliary battery voltage : READY light OFF | 12 V | |
| Output current : READY light ON | Approximately 80 A or less | |
| Water pump with motor | Battery positive terminal to terminal 1 and the battery negative terminal to terminal 2 | Water pump motor operates properly |
| IGCT relay | 7J-1 - 7J-4 | HV 10 kΩ. or higher |
| 7J-1 - 7K-4 | Below 1 Ω | |
| 7J-2 - 7J-3 | Below 1 Ω | |
| 7J-4 - 7K-1 | 10 kΩ or higher | |
| 7J-1 - 7J-4 : When battery voltage is applied to terminals 7J-2 and 7J-3 | Below 1 Ω | |
| 7J-1 - 7K-1 : When battery voltage is applied to terminals 7J-2 and 7J-3 | Below 1 Ω |