Service Data
VSC OFF Switch
VSC OFF SWITCH SERVICE DATA
| Item | Tester Connection | Switch Condition | Specified Condition |
|---|---|---|---|
| VSC OFF switch | 6-9 | Pressed | Below 1 Ω |
| Not pressed | 10 kΩ or higher |
Stop Light Control Relay
STOP LIGHT CONTROL RELAY SERVICE DATA
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 3-4 | When battery voltage is applied to terminals 1 and 2 | 10 kΩ or higher |
| When battery voltage is not applied to terminals 1 and 2 | Below 1 Ω | |
| 3-5 | When battery voltage is not applied to terminals 1 and 2 | 10 kΩ or higher |
| When battery voltage is applied to terminals 1 and 2 | Below 1 Ω |