Service Data
2AZ-FE COOLING SERVICE DATA
| Thermostat | Valve opening temperature | 80 to 84°C (176 to 183°F) |
| Valve lift | 10 mm (0.39 in.) or more at 95°C (203°F) | |
| Cooling fan motor | 7.4 to 11.4A (at 12V) 20°C (68°F) | |
| No. 2 cooling fan motor | 4.7 to 8.7A (at 12V) 20°C (68°F) | |
| No. 1 fan relay | 3-5 | 10kΩ or higher |
| Below 1Ω (when battery voltage is applied to terminals 1 and 2) | ||
| No. 2 fan relay | 3-4 | Below 1 Ω |
| 10 kΩ or higher (when battery voltage is applied to terminals 1 and 2) | ||
| 3-5 | 10 kΩ or higher | |
| Below 1 Ω (when battery voltage is applied to terminals 1 and 2) | ||
| No. 3 fan relay | 3-5 | 10 kΩ or higher |
| Below 1 Ω (when battery voltage is applied to terminals 1 and 2) | ||
| Radiator cap sub-assembly | Standard valve (for brand new cap) | 74.0 to 103.0 kPa (0.75 to 1.05 kgf/cm2 , 10.7 to 15.0 psi) |
| Minimum standard valve (for used cap) | 59.0 kPa (0.60 kgf/cm2 , 8.6 psi) |