On-Vehicle Inspection
- INSPECT FUEL PUMP RELAY
- Measure the resistance according to the value(s) in the table below.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition 3 - 4 No battery voltage applied Below 1 Ω 3 - 5 No battery voltage applied 10 kΩ or higher 3 - 4 Battery voltage applied to terminals 1 and 2 10 kΩ or higher 3 - 5 Battery voltage applied to terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the relay.
- Measure the resistance according to the value(s) in the table below.