Air Fuel Ratio Sensor: Inspection
- INSPECT AIR FUEL RATIO SENSOR
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 1 (HA1A) - 2 (+B) (Bank 1) 20°C (68°F) 1.8 to 3.4 Ω 1 (HA2A) - 2 (+B) (Bank 2) If the result is not as specified, replace the sensor.
- Measure the resistance according to the value(s) in the table below.