Stabilizer Control Valve: Disassembly
- REMOVE SERVICE VALVE CAP (for Lower Chamber Side)
- Remove the cap from the adapter housing.
- REMOVE SERVICE VALVE CAP (for Upper Chamber Side)
HINT:
Use the same procedures described for the lower chamber side.
- REMOVE OIL NOZZLE VALVE SUB-ASSEMBLY (for Lower Chamber Side)
- Remove the oil nozzle valve from the adapter housing.
- REMOVE OIL NOZZLE VALVE SUB-ASSEMBLY (for Upper Chamber Side)
HINT:
Use the same procedures described for the lower chamber side.
- REMOVE STABILIZER CONTROL ADAPTER SHUTTER VALVE (for Lower Chamber Side)
- Remove the shutter valve and O-ring from the adapter housing.
- REMOVE STABILIZER CONTROL ADAPTER SHUTTER VALVE (for Upper Chamber Side)
HINT:
Use the same procedures described for the lower chamber side.