Suspension Control System: Precaution
- Kinetic Dynamic Suspension System
CAUTION:
- Make sure to check the pipe connections and whether or not any hydraulic circuit parts are damaged before performing work, as the hydraulic circuits become highly pressurized during air bleeding.
- The pipes become highly pressurized when bleeding air. If a fluid leak is discovered, immediately release the pressure and repair the fluid leak as there is danger involved.
- Before removing, installing and disassembling hydraulic circuit parts, clean each part to prevent mud and dirt from entering the hydraulic circuit.
- Always drain fluid from the bleeder plug of the stabilizer control housing to reduce pressure before removing parts, as the fluid is sealed under high pressure in the hydraulic circuit.
- Protect the removed/disassembled parts with plastic bags to prevent foreign matter from adhering to or entering them, and store them in a safe place.
- Be careful when removing, installing and disassembling the hydraulic circuit related parts, such as bleeder plugs and tube flare nuts, as fluid may leak when the parts are damaged.