Center Differential Lock Switch: Inspection
- INSPECT CENTER DIFFERENTIAL LOCK SWITCH
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE SPECIFICATIONTester Connection Switch Condition Specified Condition 6 (L) - 9 (CPU) Switch pressed and held Below 1 Ω Switch not pressed 100 kΩ or higher If the result is not as specified, replace the center differential lock switch.