Typical Enabling Conditions
All
TYPICAL ENABLING CONDITIONS CHART
| Monitor runs whenever following DTCs not present | None |
Case 1
TYPICAL ENABLING CONDITIONS CHART
| Time after starter OFF to ON | 3 seconds or more |
| Number of camshaft position sensor signal pulse | 6 times |
| Battery voltage | 7 V or more |
| Ignition switch | ON |
Case 2
TYPICAL ENABLING CONDITIONS CHART
| Starter | OFF |
| Engine speed | 600 rpm or more |
| Time after starter from ON to OFF | 3 seconds or more |