| One of the following conditions is met: | Condition A, B or C |
| A. All of the following conditions are met: | - |
| Battery voltage | 11 V or more, and less than 13 V |
| Target duty ratio | Less than 70% |
| Output signal duty ratio | 100% or more |
| B. All of the following conditions are met: | - |
| Battery voltage | 13 V or more |
| Target duty ratio | Less than 80% |
| Output duty ratio | 100% or more |
| C. All of the following conditions are met: | - |
| Current cut status | Not cut |