Valve Body Assembly: Inspection
- INSPECT SHIFT SOLENOID VALVE S1
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE REFERENCETester Connection Condition Specified Condition Solenoid Connector (S1) - Solenoid Body (S1) 15 to 25°C (59 to 77°F) 11 to 15 Ω If the value is not as specified, replace the shift solenoid valve S1.
- Connect a positive (+) battery lead to the terminal of the solenoid connector, and a negative (-) battery lead to the solenoid body, and check the operation of the valve.NOTE: When using battery voltage during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
OK: The solenoid makes an operating sound .
If the operation cannot be done as specified, replace the shift solenoid valve S1.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE S2
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE REFERENCETester Connection Condition Specified Condition Solenoid Connector (S2) - Solenoid Body (S2) 15 to 25°C (59 to 77°F) 11 to 15 Ω If the value is not as specified, replace the shift solenoid valve S2.
- Connect a positive (+) battery lead to the terminal of the solenoid connector, and a negative (-) battery lead to the solenoid body, and check the operation of the valve.
NOTE: When using battery voltage during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.OK: The solenoid makes an operating sound .
If the operation cannot be done as specified, replace the shift solenoid valve S2.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE ST
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE REFERENCETester Connection Condition Specified Condition Solenoid Connector (ST) - Solenoid Body (ST) 15 to 25°C (59 to 77°F) 11 to 15 Ω If the value is not as specified, replace the shift solenoid valve ST.
- Connect a positive (+) battery lead to the terminal of the solenoid connector, and a negative (-) battery lead to the solenoid body, and check the operation of the valve.
NOTE: When using battery voltage during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.OK: The solenoid makes an operating sound .
If the operation cannot be done as specified, replace the shift solenoid valve ST.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE SLT
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE REFERENCETester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω If the value is not as specified, replace the shift solenoid valve SLT.
- Connect a positive (+) battery lead with a 21 W bulb to terminal 2 and a negative (-) battery lead to terminal 1 of the solenoid valve connector, and check the operation of the valve.
NOTE: When using battery voltage during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.OK: The solenoid makes an operating sound .
If the operation cannot be done as specified, replace the shift solenoid valve SLT.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE SLU
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE REFERENCETester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω If the value is not as specified, replace the shift solenoid valve SLU.
- Connect a positive (+) battery lead with a 21 W bulb to terminal 2 and a negative (-) battery lead to terminal 1 of the solenoid valve connector, and check the operation of the valve.
NOTE: When using battery voltage during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.OK: The solenoid makes an operating sound .
If the operation cannot be done as specified, replace the shift solenoid valve SLU.
- Measure the resistance according to the value(s) in the table below.