Monitor Description
The ECM IAC1 terminal voltage increases in correlation with the opening angle of the TCV. When the TCV is fully closed, approximately 0.8 V is applied to the IAC1 terminal. When the TCV is fully open, approximately 3.6 V is applied to the IAC1 terminal.
When the output voltage of the IAC1 terminal deviates from the standard range, the ECM determines that a malfunction has occurred in the position sensor and stores a DTC. Refer to ECM POWER SOURCE CIRCUIT (See ).