Service Data
Thermostat
THERMOSTAT - SERVICE DATA
| Condition | Specified Condition |
|---|---|
| Standard valve opening temperature | 80 to 84°C (176 to 183°F) |
| Standard valve lift | 10 mm (0.39 in.) or more at 95°C (203°F) |
Cooling fan motor
COOLING FAN MOTOR - SERVICE DATA
| Item | Condition | Specified Condition |
|---|---|---|
| No. 1 cooling fan motor | 20°C (68°F) | 11.7 to 14.7 A |
| No. 2 cooling fan motor | 20°C (68°F) | 11.7 to 14.7 A |
Radiator cap
RADIATOR CAP - SERVICE DATA
| Item | Condition | Specified Condition |
|---|---|---|
| Radiator reservoir cap | Standard value (for brand-new cap) | 93 to 123 kPa (1.0 to 1.3 kgf/cm2 , 13.5 to 18 psi) |
| Minimum standard value (after using cap) | 79 kPa (0.8 kgf/cm2 , 11.4 psi) |