Service Data
THERMOSTAT
THERMOSTAT - SERVICE DATA
| Condition | Specified Condition |
|---|---|
| Standard valve opening temperature | 80 to 84°C (176 to 183°F) |
| Standard valve lift | 10 mm (0.39 in.) or more at 95°C (203°F) |
COOLING FAN MOTOR
COOLING FAN MOTOR - SERVICE DATA
| Item | Indication Mark | Motor Type | Condition | Specified Condition |
|---|---|---|---|---|
| No. 1 cooling fan motor (w/o Trailer towing system) | E | 160 W | at 20°C (68°F) | 11.8 to 14.8 A |
| No. 1 cooling fan motor (w/ Trailer towing system) | H | 240 W | at 20°C (68°F) | 18.0 to 22.0 A |
| No. 2 cooling fan motor (w/o Trailer towing system) | E | 160 W | at 20°C (68°F) | 11.8 to 14.8 A |
| No. 2 cooling fan motor (w/ Trailer towing system) | H | 240 W | at 20°C (68°F) | 18.0 to 22.0 A |
COOLING FAN ECU
COOLING FAN ECU - SERVICE DATA
| Item | Tester Connection | Condition | Specified Condition |
|---|---|---|---|
| Cooling fan ECU (w/o Trailer towing system) | B12-3-Body ground | Ignition switch ON | 9 to 14 V |
| B12-1 -Body ground | Always | Below 1 Ω | |
| Cooling fan ECU (w/ Trailer towing system) | B10-1-Body ground | Ignition switch ON | 9 to 14 V |
| B11-1-Body ground | Ignition switch ON | 9 to 14 V | |
| B10-3-Body ground | Always | Below 1 Ω | |
| B11-3-Body ground | Always | Below 1 Ω |
COOLING FAN RELAY
COOLING FAN RELAY - SERVICE DATA
| Item | Tester Connection | Specified Condition |
|---|---|---|
| No. 1 fan relay | 3-5 | 10 Ω or higher |
| 3-5 | Below 1 Ω (when battery voltage is applied to terminals 1 and 2) | |
| No. 2 fan relay | 3-5 | 10 Ω or higher |
| 3-5 | Below 1 Ω (when battery voltage is applied to terminals 1 and 2) |
RADIATOR
RADIATOR - SERVICE DATA
| Item | Tester Connection | Specified Condition |
|---|---|---|
| Radiator reservoir cap | For brand-new cap | 93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2 , 13.5 to 17.8 psi) |
| After using cap | 78.5 kPa (0.8 kgf/cm2 , 11.4 psi) |