Torque Specifications
COOLANT
COOLANT - TORQUE SPECIFICATIONS
| Part Tightened | N*m | kgf*cm | ft.*lbf |
|---|---|---|---|
| Cylinder block drain cock plug x Cylinder block | 12.7 | 130 | 10 |
WATER PUMP
WATER PUMP - TORQUE SPECIFICATIONS
| Part Tightened | N*m | kgf*cm | ft.*lbf | |
|---|---|---|---|---|
| Water pump x Cylinder block | for bolt A | 21 | 214 | 15 |
| for bolt B | 9.0 | 92 | 80 in.*lbf | |
| for bolt C | 9.0 | 92 | 80 in.*lbf | |
| V-ribbed belt tensioner assembly x Cylinder block | 43 | 438 | 32 | |
| No. 2 idler pulley sub-assembly x Cylinder block | 54 | 551 | 40 | |
| Water pump pulley x Water pump | 21 | 214 | 15 | |
| Water inlet housing x Cylinder block | 10 | 102 | 7 | |
THERMOSTAT
THERMOSTAT - TORQUE SPECIFICATIONS
| Part Tightened | N*m | kgf*cm | ft.*lbf |
|---|---|---|---|
| Water inlet x Water inlet housing | 10 | 102 | 7 |
| Radiator reservoir tank x Body | 5.0 | 51 | 44 in.*lbf |
COOLING FAN MOTOR
COOLING FAN MOTOR - TORQUE SPECIFICATIONS
| Part Tightened | N*m | kgf*cm | ft.*lbf |
|---|---|---|---|
| No. 1 and No. 2 cooling fan motor x Fan shroud | 3.9 | 40 | 35 in.*lbf |
| Fan x No. 1 and No. 2 cooling fan motor | 6.3 | 64 | 55 in.*lbf |
RADIATOR
RADIATOR - TORQUE SPECIFICATIONS
| Part Tightened | N*m | kgf*cm | ft.*lbf |
|---|---|---|---|
| Fan shroud with cooling fan x Radiator | 10.5 | 107 | 8 |
| Upper radiator support x Radiator support LH and RH | 29 | 296 | 21 |
| No. 2 fan shroud x Radiator | 10.5 | 107 | 8 |
| Upper radiator support bracket x Upper radiator support | 19 | 194 | 14 |
| No. 1 water by-pass pipe x Upper radiator support | 5.0 | 51 | 44 in.*lbf |