Charging Systems: Generator: Inspection
- INSPECT GENERATOR BRUSH HOLDER ASSEMBLY
- Using vernier calipers, measure the exposed brush length.
Standard exposed length: 9.5 to 11.5 mm (0.374 to 0.453 in.)
Minimum exposed length: 1.5 mm (0.059 in.)
If the exposed length is less than the minimum, replace the generator brush holder assembly.
- Using vernier calipers, measure the exposed brush length.
- INSPECT GENERATOR REGULATOR ASSEMBLY
- Using an ohmmeter, check the continuity between terminals F and B.
Standard:
When the positive and negative poles between terminals F and B are exchanged, there is continuity in one direction but no continuity in the other direction.
If the continuity is not as specified, replace the generator regulator assembly.
- Using an ohmmeter, check the continuity between terminals F and E.
Standard:
When the positive and negative poles between terminals F and E are exchanged, there is continuity in one direction but no continuity in the other direction.
If the continuity is not as specified, replace the generator regulator assembly.
- Using an ohmmeter, check the continuity between terminals F and B.
- INSPECT GENERATOR DRIVE END FRAME
- Check the stator coil for open circuits.
- Using an ohmmeter, check the resistance between the coil leads.
Standard resistance: Below 1 Ω
If the result is not as specified, replace the generator assembly.
- Using an ohmmeter, check the resistance between the coil leads.
- Inspect the stator for ground.
- Using an ohmmeter, check the resistance between the coil lead and drive end frame.
Standard resistance: 10 kΩ or higher
If the result is not as specified, replace the generator assembly.
- Using an ohmmeter, check the resistance between the coil lead and drive end frame.
- Inspect the bearing.
- Make sure that the bearing is not rough or worn.
If necessary, replace the generator assembly.
- Make sure that the bearing is not rough or worn.
- Check the stator coil for open circuits.
- INSPECT GENERATOR HOLDER WITH RECTIFIER
- Using an ohmmeter, check the continuity among terminals P1, P2, P3 and B, and among P1, P2, P3 and E.
Standard:
When the positive and negative poles among terminals P1, P2, P3 and B are exchanged, there is continuity in one direction but no continuity in the other direction.
When the positive and negative poles among terminals P1, P2, P3 and E are exchanged, there is continuity in one direction but no continuity in the other direction.
If the continuity is not as specified, replace the generator holder with rectifier.
- Using an ohmmeter, check the continuity among terminals P1, P2, P3 and B, and among P1, P2, P3 and E.
- INSPECT GENERATOR ROTOR ASSEMBLY
- Check the generator rotor for open circuits.
- Using an ohmmeter, measure the resistance between the slip rings.
Standard resistance: 1.7 to 2.1 Ω at 20°C (68°F)
If the resistance is not as specified, replace the generator rotor assembly.
- Using an ohmmeter, measure the resistance between the slip rings.
- Check the generator rotor for short circuits.
- Using an ohmmeter, check the resistance between the slip ring and generator rotor assembly.
Standard resistance: 10 kΩ or higher
If the result is not as specified, replace the generator rotor assembly.
- Using an ohmmeter, check the resistance between the slip ring and generator rotor assembly.
- Inspect the slip rings.
- Make sure that the slip rings are not rough or scored.
If rough or scored, replace the generator rotor assembly.
- Using vernier calipers, measure the slip ring diameter.
Standard diameter: 14.2 to 14.4 mm (0.559 to 0.567 in.)
Minimum diameter: 12.8 mm (0.504 in.)
If the diameter is less than the minimum, replace the generator rotor assembly.
- Make sure that the slip rings are not rough or scored.
- Check the generator rotor for open circuits.