Data List / Active Test
- DATA LIST
HINT:
Using Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or writing is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
NOTE:In the table below, the values listed under "Normal Condition" are reference value. Do not depend solely on these reference values when deciding whether a part is faulty or not.
- Connect Techstream to the DLC3.
- Turn the ignition switch on (IG).
- Enter the following menus: Body Electrical / Air Conditioner / Data List.AIR CONDITIONER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Room Temperature Sensor Room temperature sensor / min.: -6.5°C (20.3°F) max.: 57.25°C (135.05°F) Actual cabin temperature is displayed - Ambient Temp Sensor Ambient temperature sensor / min.: -23.3°C (-9.94°F) max.: 65.95°C (150.71°F) Actual cabin temperature is displayed - Solar Sensor (D side) Solar sensor (Driver side) / min.: 0 max.: 255 Increases as brightness increases - Solar Sensor (P side) Solar sensor (Passenger side) / min.: 0 max.: 255 Increases as brightness increases - Engine Coolant Temp Engine coolant temperature sensor / min.: 1.3°C (34.34°F) max.: 90.55°C (194.99°F) Actual engine coolant temperature is displayed while the engine is displayed warmed up - Set Temperature (D side) Set temperature (Driver side) / min.: 0 max.: 255 Actual set temperature is displayed (driver side) - Set Temperature (P side) Set temperature (Passenger side) / min.: 0 max.: 255 Actual set temperature is displayed (Passenger side) - Blower Motor Speed Level Blower motor speed level / min.: 0 level max.: 31 level Increases in the range between 0 and 31 as the speed increases - Adjusted Ambient Temp Adjusted ambient temperature (Passenger side) / min.: -30.8°C (-23.44°F) max.: 50.8°C (123.44°F) - - Evaporator Fin Thermistor Evaporator temperature sensor / min.: -29.7°C (-21.46°F) max.: 59.55°C(139.19°F) Actual evaporator temperature displayed - Shift Set Temperature Shift set temperature / +2C, +1C, NORMAL, -1C, -2C Customized value will be displayed - Air Inlet Mode Air inlet mode / AUTO, MANUAL Customized value will be displayed - Compressor Mode Compressor mode / AUTO, MANUAL Customized value will be displayed - Compressor / DEF Mode Compressor / DEF operation mode / LINK, NORMAL Customized value will be displayed - Evaporator Control Evaporator control / AUTO, MANUAL Customized value will be displayed - Button Press Buzzer Button press buzzer / ON, OFF Customized value will be displayed - Foot Air Leak Foot air leak / ON, OFF Customized value will be displayed - Foot / DEF Auto Blow Up Foot / DEF automatic blow up function /ON, OFF Customized value will be displayed - Foot / DEF Auto Mode Foot / DEF mode / ON, OFF Customized value will be displayed - Ambient Temperature Shift Ambient temperature Shift / +3C, +2C, +1C, Normal, -1C, -2C, -3C Customized value will be displayed - Regulator Pressure Sensor Regulator pressure sensor / min.: -0.45668 MPaG max.: 3.29437 MPaG Actual regulator Pressure is displayed - Regulator Control Current Regulator control current / min.: 0 A max.: 255 A - - Air Mix Servo Targ Pulse (D) Air mix servomotor target pulse (D side) / min.: 0, max.: 255 Damper is at "MAX. COOL" : 5 (pulse)
Damper is at "MAX. HOT" : 103 (pulse)- Air Mix Servo Targ Pulse (P) Air mix servomotor target pulse (P side) / min.: 0, max.: 255 Damper is at "MAX. COOL" : 105 (pulse)
Damper is at "MAX. HOT" : 7 (pulse)- Air Outlet Servo Pulse (D) Air outlet servomotor target pulse (D side) / min.: 0, max.: 255 Damper is at "FACE" : 8 (pulse)
Damper is at "B/L" : 30 (pulse)
Damper is at "FOOT" : 67 (pulse)
Damper is at "F/D" : 80 (pulse)
Damper is at "DEF" : 97 (pulse)- Air Inlet Damper Targ Pulse Air inlet damper target pulse / min.: 0, max.: 255 Damper is at "RECIRCULATION" : 7 (pulse)
Damper is at "FRESH" : 28 (pulse)- Number of Trouble Codes Number of Trouble / min.: 0, max.: 255 Number of DTCs will be displayed -
- ACTIVE TEST
HINT:
Using Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
It is possible to display the Data List on Techstream during the Active Test.
- Connect Techstream to the DLC3.
- Turn the ignition switch on (IG).
- Enter the following menus: Body Electrical / Air Conditioner / Active Test.AIR CONDITIONER
Tester Display Test Part Control Range Blower Motor Blower motor / min.:0, max.: 31 level - Magnetic Clutch Relay Magnetic clutch relay / OFF, ON - Defogger Relay (Rear) Defogger relay (Rear) / OFF, ON - Air Mix Servo Targ Pulse(D) Air mix servomotor pulse (D side) / min.: 0, max.: 255 - Air Mix Servo Targ Pulse (P) Air mix servomotor pulse (P side) / min.: 0, max.: 255 - Air Outlet Servo Pulse (D) Air outlet servomotor pulse (D side) / min.: 0, max.: 255 - Air Inlet Damper Targ Pulse Air inlet damper tamper target pulse / min.: 0, max.: 255 -