Steering Column Assembly: Inspection: Inspection
NOTE:
When using a vise, do not overtighten it.
- INSPECT PRELOAD
- Secure the steering column assembly in a vise.
- Using SST, turn the main shaft and measure the preload.
- SST: 09616-00011
Preload (for Brush Type Motor)
Torque: 1.1 N*m (11 kgf*cm, 10 in.*lbf)
or less
Preload (for Brushless Type Motor)
Torque: 0.9 to 1.5 N*m (10 to 15 kgf*cm, 8 to 12 in.*lbf)
If the preload is not as specified, replace the steering column assembly with a new one.
- INSPECT BUSHING