Home >> Toyota >> 2010 >> Sienna XLE, AWD >> Repair and Diagnosis >> Body & Frame >> Windows >> Power Window Control System (W/ Jam Protection Function) (Diagnostics & Symptom Tests) >> POWER WINDOW CONTROL SYSTEM (w/ Jam Protection Function) >> Symptom Tests >> Remote Up / Down Function does not Operate >> Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Remote Up / Down Function does not Operate: Procedure

  1. CHECK POWER WINDOW LOCK SWITCH 
    1. Push the window lock switch OFF (normal) and check that the remote UP/DOWN function operates.
      Fig 1: Identifying Lock Switch
      GTY214098Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    OK → END 

    NG: Go to next step 

  2. CHECK MANUAL UP/DOWN FUNCTION 
    1. Check that the passenger side door window and slide door windows can be operated via each regulator switch.

    NG → OTHER PROBLEM 

    OK: Go to next step 

  3. INSPECT POWER WINDOW MASTER SWITCH 

    HINT: 

    Inspect the switch with the nonoperational remote function.

    1. Remove the master switch.
      Fig 2: Identifying Power Window Master Switch Connector Terminals
      GTY238691Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Check the resistance between the terminals of the master switch when each switch is operated, as shown in the table below.

      Standard resistance

      Passenger side switch 

      Rear LH switch 

      Rear RH switch 

      Window Lock Switch Power Window Switch Terminal No. Specified Condition
      OFF (Normal) UP 1 - 15, 6 - 13 Below 1 Ω
      OFF 1 - 13 - 15
      DOWN 1 - 13, 6 - 15
      ON (Lock) UP 6 - 13
      OFF 13 - 15
      DOWN 6 - 15
      Window Lock Switch Power Window Switch Terminal No. Specified Condition
      OFF (Normal) UP 1 - 10, 6 - 12 Below 1 Ω
      OFF 1 - 10 - 12
      DOWN 1 - 12, 6 - 10
      ON (Lock) UP 6 - 12
      OFF 10 - 12
      DOWN 6 - 10
      Window Lock Switch Power Window Switch Terminal No. Specified Condition
      OFF (Normal) UP 1 - 16, 6 - 18 Below 1 Ω
      OFF 1 - 16 - 18
      DOWN 1 - 18, 6 - 16
      ON (Lock) UP 6 - 18
      OFF 16 - 18
      DOWN 6 - 16

    NG → REPLACE POWER WINDOW MASTER SWITCH 

    OK → REPAIR OR REPLACE HARNESS AND CONNECTOR (MASTER SWITCH - EACH REGULATOR SWITCH)