Installation (To 12/2010): Installation
- INSTALL ATF TEMPERATURE SENSOR ASSEMBLY
- Coat a new O-ring with ATF and install it to the ATF temperature sensor assembly.
- Coat the 4 bolts with ATF.
- Install the ATF temperature sensor assembly and clamp to the valve body with the 4 bolts.
Torque: 11 N*m (112 kgf*cm, 8 ft.*lbf)
Bolt length
Bolt A
25 mm (0.98 in.)
Bolt B
85 mm (3.35 in.)
- Connect the connector.
- INSTALL VALVE BODY OIL STRAINER ASSEMBLY See step 3
- INSTALL AUTOMATIC TRANSAXLE OIL PAN SUB-ASSEMBLY See step 4
- INSTALL AUTOMATIC TRANSAXLE ASSEMBLY
HINT:
See step 10.