Back Door Entry Lock Function does not Operate: Procedure
- CHECK POWER DOOR LOCK OPERATION
- When the door control switch of the master switch assembly is operated, check that the locked doors unlock.
OK
Door locks operate normally.
NG → See step 5
OK: Go to next step
- When the door control switch of the master switch assembly is operated, check that the locked doors unlock.
- READ VALUE USING TECHSTREAM (BACK DOOR LOCK SWITCH)
- Using the Techstream, read the Data List.SMART KEY
Tester Display Measurement Item/Display Normal Condition Diagnostic Note Tr/B-Door Lock SW Back door lock switch / ON or OFF ON: Back door lock switch is pushed
OFF: Back door lock switch is not pushed- OK
"ON" (switch is pushed) or "OFF" (switch is not pushed) appears on the screen.
NG → See step 3
OK → REPLACE CERTIFICATION ECU (SMART KEY ECU ASSEMBLY)
- Using the Techstream, read the Data List.
- CHECK BACK DOOR OPENER SWITCH
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 (UL) - 2 (L) Lock switch pushed Below 1 Ω 1 (UL) - 2 (L) Lock switch not pushed 10 kΩ or higher
NG → See step 6
OK: Go to next step
- Measure the resistance according to the value(s) in the table below.
- CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU [SMART KEY ECU ASSEMBLY] - BACK DOOR OPENER SWITCH)
- Disconnect the E29 ECU connector.
- Disconnect the S7 switch connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition E29-7 (TSW5) - S7-1 (UL) Always Below 1 Ω E29-7 (TSW5) - Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → REPLACE CERTIFICATION ECU (SMART KEY ECU ASSEMBLY)
- GO TO POWER DOOR LOCK CONTROL SYSTEM. Refer to OPERATION CHECK
- REPLACE BACK DOOR OPENER SWITCH. Refer to REMOVAL