DTC P060B: Internal Control Module A/D Processing Performance: Procedure
- CHECK DTC
- Clear DTC. Refer to DTC CHECK / CLEAR .
- Turn the ignition switch off.
- Disconnect the cable from the negative (-) battery terminal and wait for 1 minute.
- Connect the cable to the negative (-) battery terminal.
- Turn the ignition switch to ON.
- Check DTC.RESULT
Result Proceed to DTC is not output A DTC P060B is output B DTC P060B and P0327, P0328 are output C
B → See step 3
C → See step 4
A → See step 2
- Refer to CHECK FOR INTERMITTENT PROBLEMS
- REPLACE ECM. Refer to REMOVAL
- GO TO DTC (P0327, P0328). Refer to DTC P0327: Knock Sensor 1 Circuit Low Input (Bank 1 or Single Sensor); DTC P0328: Knock Sensor 1 Circuit High Input (Bank 1 or Single Sensor)