| Air-fuel ratio compensation system |
Voltage |
E11-1 (A1A+) - E11-12 (E1) |
3.3 V |
| E11-7 (A2A+) - E11-12 (E1) |
3.3 V |
| E11-2 (A1A-) - E11-12 (E1) |
2.9 V |
| E11-8 (A2A-) - E11-12 (E1) |
2.9 V |
| Canister Pump Module (Pressure Sensor) |
Voltage |
E9-15 (VCV1) - E10-8 (ETHW) |
4.5 to 5.0 V |
| E10-1 (PPMP) - E10-8 (ETHW) |
3.0 to 3.6 V |
| Vacuum Switching Valve No. 1 |
Resistance |
at 20 °C (68 °F) |
26 to 30 Ω |
| Air fuel ratio sensor (Bank 1) |
Resistance |
1 (HA1A) - 2 (+B) |
1.8 to 3.4 Ω at 20°C (68°F) |
| 1 (HA1A) - 4 (A1A-) |
10 kΩ or higher |
| Air fuel ratio sensor (Bank 2) |
Resistance |
1 (HA2A) - 2 (+B) |
1.8 to 3.4 Ω at 20°C (68°F) |
| 1 (HA2A) - 4 (A2A-) |
10 kΩ or higher |
| Heated oxygen sensor No. 2 (Bank 1) |
Resistance |
1 (HT1B) - 2 (+B) |
11 to 16 Ω at 20°C (68°F) |
| Resistance |
1 (HT1B) - 4 (E2) |
10 kΩ or higher |
| Heated oxygen sensor No. 2 (Bank 2) |
Resistance |
1 (HT2B) - 2 (+B) |
11 to 16 Ω at 20°C (68°F) |
| Resistance |
1 (HT2B) - 4 (E2) |
10 kΩ or higher |