| U0073 |
When either of following conditions (1 or 2) detected:
- After data output from skid control ECU completed, output continues for 5 seconds or more.
- Bus off condition occurs once or more per 0.1 seconds 10 times in succession.
|
CAN communication system |
| U100 |
When IG1 terminal voltage 10 V or more and vehicle speed 9 mph (15 km/h) or more, either of following conditions (1 or 2) occurs 10 times in succession:
- Data cannot be sent to ECM once or more within 5 seconds.
- Data from ECM cannot be received once or more within 5 seconds.
|
CAN communication system |
| U0123 |
When IG1 terminal voltage 10 V or more, either of following conditions (1 or 2) detected:
- Data from yaw rate sensor cannot be received for 1 second or more.
- Data from yaw rate sensor cannot be received once or more within 5 seconds.
|
CAN communication system |
| U0124 |
When IG1 terminal voltage 9.5 V or more, either of following conditions (1 or 2) detected:
- Data from acceleration sensor cannot be received for 1 second or more.
- Data from acceleration sensor cannot be received once or more within 5 seconds.
|
CAN communication system |
| U0126 |
When IG1 terminal voltage 10 V or more, either of following conditions (1 or 2) detected:
- Data from steering angle sensor cannot be received for 1 second or more.
- Data from steering angle sensor cannot be received once or more within 5 seconds.
|
CAN communication system |