Battery Standard specific gravity 1.25 to 1.29 at 20°C (68°F)
Charging circuit without load Standard current 10 A or less
Standard voltage 13.2 to 14.8 V
(when engine speed at 2000 rpm)
Charging circuit with load Standard current 30 A or higher
Generator brush holder Standard exposed length 9.5 to 11.5 mm (0.374 to 0.453 in.)
Minimum exposed length 4.5 mm (0.177 in.)
Generator rotor Standard resistance Slip ring - Slip ring 2.3 to 2.7 Ω
Slip ring - Rotor core 10 MΩ or higher
Standard diameter 14.2 to 14.4 mm (0.559 to 0.567 in.)
Minimum diameter 14.0 mm (0.551 in.)