Typical Enabling Conditions
WARNING: This page is about a different variant/trim than selected.
ALL
| Monitor runs whenever following DTCs are not stored | None |
AFTER ENGINE STOP
| Time after engine start | 10 seconds or more |
| Auxiliary battery voltage | 10.5 V or more |
| Engine coolant temperature at ECM started by internal engine off timer | -40°C (-40°F) or more |
| Intake air temperature circuit fail (P0112, P0113) | Not detected |
| Engine coolant temperature sensor circuit fail (P0115, P0117, P0118) | Not detected |
| Mass air flow meter circuit fail (P0102, P0103) | Not detected |
| Engine water pump circuit fail (P261B, P261C, P261D) | Not detected |
| Soak timer circuit fail (P2610) | Not detected |
| Engine coolant temperature before engine stop | 70°C (158°F) or more |
| Accumulated mass air flow amount before engine stop | 1900 g or more |
| Key-off duration | 30 minutes |
AFTER COLD ENGINE START
| Key-off duration | 5 hours or more |
| Time after engine start | 10 seconds or more |
| Intake air temperature circuit fail (P0112, P0113) | Not detected |
| Engine coolant temperature sensor circuit fail (P0115, P0117, P0118) | Not detected |
| Mass air flow meter circuit fail (P0102, P0103) | Not detected |
| Engine water pump circuit fail (P261B, P261C, P261D) | Not detected |
| Soak timer circuit fail (P2610) | Not detected |
| Engine coolant temperature | 70°C (158°F) or more |
| Accumulated mass air flow amount | 1900 g or more |
| Either of the following conditions 1 or 2 is met: | - |
| 1. Duration while engine load is low | 120 seconds or more |
| 2. Duration while engine load is high | 10 seconds or more |