Service Data
RESERVE TANK CAP (FOR INVERTER)
| Item | Specified Condition |
|---|---|
| Standard value (for brand-new cap) | 94 to 122 kPa (1.0 to 1.2 kgf/cm2 , 13.6 to 17.7 psi) |
| Minimum standard value (for used cap) | 94 kPa (1.0 kgf/cm2 , 13.6 psi) |
RELAY
| Item | Tester Connection | Specified Condition |
| No. 1 circuit breaker sensor | 1 (SIF-) - 2 (SIF+) | 0.65 to 1.0 kΩ at 20°C (68°F) |
| IGCT relay Resistance |
3 - 5 | 10 kΩ or higher (When battery voltage is not applied between terminals 1 and 2) |
| 3 - 5 | Below 1 Ω (When battery voltage is applied between terminals 1 and 2) |
HYBRID BATTERY JUNCTION BLOCK
| SMRB Resistance |
4 (SMRB) - 2 (GND) | 19.0 to 35.5 Ω (at -40°C (-40°F) to 80°C (176°F)) |
| SMRG Resistance |
1 (SMRG) - 2 (GND) | 19.0 to 35.5 Ω (at -40°C (-40°F) to 80°C (176°F)) |
| SMRP Resistance |
3 (SMRP) - 2 (GND) | 112 to 274 Ω (at -40°C (-40°F) to 80°C (176°F)) |
| Precharge resistor |
- | 28.5 to 31.5 Ω |
| Electric vehicle fuse | - | Below 1 Ω |
SERVICE PLUG GRIP
| Service plug grip | - | Below 1 Ω |