Service Data
STOP LIGHT CONTROL (BRK) RELAY
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 3 - 4 | Voltage is not applied between terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 4 | Voltage is applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Voltage is applied between terminals 1 and 2 | Below 1 Ω |
VSC OFF SWITCH
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 6 (+) - 3 (E) | Switch is pushed in | Below 1 Ω |
| 6 (+) - 3 (E) | Switch is not pushed in | 10 kΩ or higher |
BRAKE PEDAL LOAD SENSING SWITCH
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 2 (FSW+) - 1(GND) | Brake pedal load sensing switch OFF (Brake pedal depressed) | 950 to 1050 Ω |
| 2 (FSW+) - 1(GND) | Brake pedal load sensing switch ON (Brake pedal released) | 203 to 223 Ω |