Service Data

Starter Specified current 90 A or less at 11.5 V
Brush Standard length 15.5 mm (0.610 in.)
Minimum length 8.5 mm (0.335 in.)
Starter armature Circle runout Maximum 0.05 mm (0.00197 in.)
Commutator Standard diameter 30.0 mm (1.18 in.)
Minimum diameter 29.0 mm (1.14 in.)
Standard undercut depth 0.6 mm (0.0236 in.)
Minimum undercut depth 0.2 mm (0.00787 in.)
Starter brush holder assembly Standard spring load 18 to 24 N (1.8 to 2.4 kgf, 4.0 to 5.3 lbf)