DTC P050B: Cold Start Ignition Timing Performance: Description
This monitor will run when the engine is started at an engine coolant temperature of -10 to 50°C (14 to 122°F). The DTC will be stored after the engine idles for 13 seconds (2 trip detection logic).
The DTC is designed to monitor the ignition timing at cold start. When the engine is started at an engine coolant temperature of lower than 50°C (122°F), the ECM checks the ignition timing at engine idling. If the ignition timing advances beyond the specified level within 10 seconds, the ECM interprets this as a malfunction. The MIL is illuminated and a DTC is stored when the malfunction is detected in consecutive driving cycles (2 trip detection logic).
When performing the Learning Value Reset* during inspections or repairs, the idle speed control learned values are cleared. This DTC cannot be stored with the idle speed control learned values cleared.
HINT:
The idle speed control learning* is performed when the engine is warmed up and has been idling for 5 minutes.
*: Refer to Initialization. Refer to INITIALIZATION .
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P050B | Insufficient ignition timing retard at cold start (2 trip detection logic) |
|