Monitor Description
The ECM illuminates the MIL and sets a DTC when either one of the following conditions, which could cause emission control system performance deterioration, is detected (2 trip detection logic).
- Within the first 1000 crankshaft revolutions of the engine starting, an excessive misfiring rate (approximately 20 to 50 misfires per 1000 crankshaft revolutions) occurs once.
- An excessive misfiring rate (approximately 20 to 50 misfires per 1000 crankshaft revolutions) occurs a total of 4 times.
The ECM flashes the MIL (immediate detection logic) and sets a DTC (2 trip detection logic) when either one of the following conditions, which could cause the three-way catalytic converter damage, is detected.
HINT:
If a catalyst damage misfire occurs, the monitor informs the driver by blinking the MIL (1 trip).
- In every 200 crankshaft revolutions at a high engine speed, the threshold misfiring percentage is recorded once.