Millimeter Wave Radar Sensor Power Source Circuit: Procedure
- CHECK MILLIMETER WAVE RADAR SENSOR ASSEMBLY (IGB VOLTAGE)
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- Disconnect the millimeter wave radar sensor assembly connector.
- Turn the power switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition A2-5 (IGB) - A2-2 (SGND) Power switch on (IG) 10 to 14 V TEXT IN ILLUSTRATION*1 Front view of wire harness connector
(to Millimeter Wave Radar Sensor Assembly) - Reconnect the millimeter wave radar sensor assembly connector.
NG → See step 2
OK → See step 3
- CHECK HARNESS AND CONNECTOR (MILLIMETER WAVE RADAR SENSOR ASSEMBLY - BODY GROUND)
- Disconnect the millimeter wave radar sensor assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open)
Tester Connection Condition Specified Condition A2-2 (SGND) - Body ground Always Below 1 Ω TEXT IN ILLUSTRATION*1 Front view of wire harness connector
(to Millimeter Wave Radar Sensor Assembly) - Reconnect the millimeter wave radar sensor assembly connector.
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR (MILLIMETER WAVE RADAR SENSOR ASSEMBLY - BODY GROUND)
OK → REPAIR OR REPLACE HARNESS OR CONNECTOR (MILLIMETER WAVE RADAR SENSOR ASSEMBLY - IG1 NO. 1 RELAY)
- PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE