Customize Parameters
- CUSTOMIZE FUNCTION WITH TECHSTREAM
HINT:
The following items can be customized.
NOTE:- When the customer requests a change in a function, first make sure that the function can be customized.
- Record the current settings before customizing.
- When troubleshooting a function, first make sure that the function is set to the default setting.
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Main Body / Utility / Customize Setting.
- Select the setting by referring to the table below.MAIN BODY
Tester Display Default Content Setting Seat Move Distance Standard Allows customization of the seat movement distance for the power easy access system. OFF, Little or Standard Seat position/Tilt & Telesco memory recall setting D Door This customize function switches the condition of the seat position, mirror position and tilt and telescopic memory recall. Possible recall activation parameters are "driver door unlocked with smart entry and start system and opened" or "any door unlocked with smart entry and start system and opened". D Door or ANY Door