Combination Meter ECU Communication Stop Mode [08/2013 - ]: Procedure
- PRECAUTION NOTE:
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work. Refer to PRECAUTION [08/2013 - ] .
NEXT: Go to next step
- DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
- Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the main wire and the branch wire.WARNING:
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.
NOTE:When disconnecting the cable, some systems need to be initialized after the cable is reconnected. Refer to INITIALIZATION [08/2013 - ]
NEXT: Go to next step
- Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the main wire and the branch wire.
- CHECK FOR OPEN IN CAN BUS WIRE (COMBINATION METER ASSEMBLY (COMBINATION METER ECU) MAIN WIRE)
- Turn the ignition switch off.
- Disconnect the combination meter assembly (combination meter ECU) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition E14-10 (CANH) - E14-9 (CANL) Ignition switch off 108 to 132 Ω TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Combination Meter Assembly (Combination Meter ECU))
NG → REPAIR OR REPLACE CAN MAIN WIRE OR CONNECTOR (CAN-H, CAN-L)
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY (COMBINATION METER ECU) - BATTERY AND BODY GROUND)
- Connect the cable to the negative (-) battery terminal.NOTE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected. Refer to INITIALIZATION [08/2013 - ]
- Disconnect the E13 combination meter assembly (combination meter ECU) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition E13-21 (ES) - Body ground Always Below 1 Ω TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Combination Meter Assembly (Combination Meter ECU)) - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition E13-2 (IG+) - Body ground Ignition switch ON 11 to 14 V E13-1 (B) - Body ground Always 11 to 14 V
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 5
- Connect the cable to the negative (-) battery terminal.
- REPLACE COMBINATION METER ASSEMBLY (COMBINATION METER ECU). Refer to REMOVAL [08/2013 - ]