Power Source Mode does not Change to ON (IG and ACC) [12/2013 - ]: Description
If any of the following operations are performed, the power management control ECU receives a signal, and changes the power source mode.
- With the electrical key transmitter sub-assembly in the cabin, the power switch is pressed.
- When the auxiliary battery of the electrical key transmitter sub-assembly is depleted, the brake pedal is depressed and the electrical key transmitter sub-assembly is held near the power switch.
- When the smart key system cancel function has been canceled on the customization menu, the brake pedal is depressed and the electrical key transmitter sub-assembly is held near the power switch.
HINT:
- When the cable is disconnected and reconnected to the negative (-) battery terminal, the power source mode returns to the state it was in before the cable was disconnected.
- If the room oscillator does not recognize the key, the cause of the malfunction may be stored in the certification ECU (smart key ECU assembly). Refer to OPERATION HISTORY LIST [12/2013 - ] .
- If the cause of the malfunction is stored in the certification ECU (smart key ECU assembly), the following table is helpful in checking whether or not the malfunction was caused by wave interference.
RADIO WAVE INTERFERENCE:
| Problem Symptom | Data List Item |
|---|---|
| Operating Engine Switch / Key RF Signal Interference |
|