DTC B1796: Sleep Operation Failure of Occupant Classification ECU [10/2013 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- REPLACE OCCUPANT DETECTION ECU
- Turn the power switch off.
- Disconnect the cable from the negative (-) auxiliary battery terminal.
- Replace the occupant detection ECU. Refer to REMOVAL [10/2013 - ] .
- Connect the cable to the negative (-) auxiliary battery terminal.
NEXT: Go to next step
- PERFORM ZERO POINT CALIBRATION
- Using the Techstream, perform Zero Point Calibration. Refer to INITIALIZATION [10/2013 - ] .
NEXT: Go to next step
- PERFORM SENSITIVITY CHECK
- Using the Techstream, perform Sensitivity Check. Refer to INITIALIZATION [10/2013 - ] .
NEXT → END