Inspection Procedure
If any of the following conditions are not met, EV mode may not be turned on or the mode may be canceled. (A buzzer sounds to indicate that the transition to EV mode is canceled and a message is displayed on multi-information display.)
| EV Mode Entry Condition | Tester Display | Specified Condition |
|---|---|---|
| HV battery charge level | State of Charge | Approximately 50% or higher |
| Accelerator pedal position | Accelerator Degree | Below approximately 30% |
| Engine coolant temperature | Engine Coolant Temp | 68°F (20°C) or higher |
| HV battery temperature | Temp of Batt TB1 to TB3 | Between 50°F to 104°F (10°C to 40°C) |
| Vehicle speed (Varies depending on engine warm-up condition) |
- | Cold: 10 mph (16km/h) Warmed-up: 25 mph (40km/h) |
| Defroster | - | OFF |
| Cruise control | - | OFF |
| Win | Charge Control Value | Below -20000W |
| Wout | Discharge Control Value | 20000W or higher |