Back Door Entry Unlock Function does not Operate [09/2013 - ]: Procedure
- CHECK FOR DTC
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- By following the Techstream screen display, check whether any DTCs are output.
OK
DTC is not output.
NG → Go to CORRESPONDING SYSTEM
OK: Go to next step
- CHECK POWER DOOR LOCK CONTROL SYSTEM
- Check that the power door lock functions operate normally. Refer to OPERATION CHECK [09/2013 - ]
.
OK
All doors can be unlocked with door control switch.
NG → See step 12
OK: Go to next step
- Check that the power door lock functions operate normally. Refer to OPERATION CHECK [09/2013 - ]
.
- CHECK WIRELESS DOOR LOCK CONTROL SYSTEM
- Check that the wireless door lock functions operate normally. Refer to OPERATION CHECK [09/2013 - ]
.
OK
Wireless door lock functions operate normally.
NG → See step 13
OK: Go to next step
- Check that the wireless door lock functions operate normally. Refer to OPERATION CHECK [09/2013 - ]
.
- READ VALUE USING TECHSTREAM (DOOR COURTESY SWITCH)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Main Body / Data List.
- Read the Data List according to the display on the Techstream.MAIN BODY
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Back Door Courtesy SW Back door courtesy light switch signal / ON or OFF ON: Back door is open
OFF: Back door is closed- OK
On Techstream screen, item changes between ON and OFF according to above chart.
NG → See step 14
OK: Go to next step
- PERFORM ACTIVE TEST USING TECHSTREAM (BACK DOOR SELECT)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Smart Key / Active Test.
- According to the display on the Techstream, perform the Active Test.SMART KEY
Tester Display Test Part Control Range Diagnostic Note Back Door Select Back door electrical key oscillator ON or OFF - OK
ON (Back Door Select is ON) appears on screen.
NG → See step 15
OK: Go to next step
- READ VALUE USING TECHSTREAM (TOUCH SENSOR)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Smart Key / Data List.
- Read the Data List according to the display on the Techstream.SMART KEY
Tester Display Measurement Item/Range Normal Condition Diagnostic Note B-Door Touch Sensor Back door touch sensor / ON or OFF ON: Sensor is touched
OFF: Sensor is not touched- OK
When back door sensor is set to ON, ON (sensor is touched) appears on screen.
NG → See step 8
OK: Go to next step
- CHECK CERTIFICATION ECU (ECU AGGREGATION BOX ASSEMBLY) (OPERATION)
- Temporarily replace the certification ECU (ECU aggregation box assembly) with a new or normally functioning one.
- Check that the entry back door unlock function operates normally.
OK
Entry back door unlock function operates normally.
NG → REPLACE MAIN BODY ECU (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
OK → END (CERTIFICATION ECU [ECU AGGREGATION BOX ASSEMBLY] WAS DEFECTIVE)
- CHECK BACK DOOR ELECTRICAL KEY OSCILLATOR
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Smart Key / Active Test / Back Door Select.
- Operate the certification ECU (ECU aggregation box assembly) using the Active Test function and measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition 37 (SEL9) - Body ground During Active Test Below 1 V 26 (SEN9) - Body ground Touch sensor is touched during Active Test Below 1 V Touch sensor is not touched during Active Test 11 to 14 V TEXT IN ILLUSTRATION*a Component with harness connected
(Certification ECU [ECU Aggregation Box Assembly])
NG → See step 9
OK → See step 15
- Connect the Techstream to the DLC3.
- CHECK HARNESS AND CONNECTOR (BACK DOOR ELECTRICAL KEY OSCILLATOR - ELECTRICAL KEY ANTENNA)
- Disconnect the Q11 back door electrical key oscillator connector.
- Disconnect the Q12 electrical key antenna connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Q11-2 (SGT) - Q12-6 (SGT) Always Below 1 Ω Q11-3 (ANT1) - Q12-5 (ANT1) Q11-8 (ANT2) - Q12-2 (ANT2) Q11-9 (TRG-) - Q12-1 (TRG-) Q11-2 (SGT) - Body ground Always 10 kΩ or higher Q11-3 (ANT1) - Body ground Q11-8 (ANT2) - Body ground Q11-9 (TRG-) - Body ground
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU [ECU AGGREGATION BOX ASSEMBLY] - BACK DOOR ELECTRICAL KEY OSCILLATOR)
- Disconnect the E84 certification ECU (ECU aggregation box assembly) connector.
- Disconnect the Q11 back door electrical key oscillator connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition E84-37 (SEL9) - Q11-4 (SEL) Always Below 1 Ω E84-26 (SEN9) - Q11-6 (SENS) E84-31 (CLG9) - Q11-10 (CLG) E84-32 (CG9B) - Q11-5 (CLGB) E84-37 (SEL9) - Body ground Always 10 kΩ or higher E84-26 (SEN9) - Body ground E84-31 (CLG9) - Body ground E84-32 (CG9B) - Body ground
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 11
- REPLACE BACK DOOR ELECTRICAL KEY OSCILLATOR. Refer to REMOVAL [09/2013 - ]
- Go to POWER DOOR LOCK CONTROL SYSTEM. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [09/2013 - ]
- Go to WIRELESS DOOR LOCK CONTROL SYSTEM. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [09/2013 - ]
- Go to LIGHTING SYSTEM. Refer to PROBLEM SYMPTOMS TABLE [09/2013 - ]
- REPLACE CERTIFICATION ECU (ECU AGGREGATION BOX ASSEMBLY). Refer to REMOVAL [09/2013 - ]