Auto Up Operation does not Fully Close Power Window (Jam Protection Function is Activated) [09/2013 - ]: Procedure
- PERFORM INITIALIZATION
- Initialize the front power window regulator motor assembly LH. Refer to INITIALIZATION [09/2013 - ] .
NEXT: Go to next step
- CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP/DOWN FUNCTION)
- Check that the driver side power window moves when the auto up and down functions of the power window regulator master switch assembly are operated. Refer to OPERATION CHECK [09/2013 - ]
.
OK
Auto up and down function is normal.
NG → See step 3
OK → END (PROBLEM DUE TO INITIALIZATION FAILURE)
- Check that the driver side power window moves when the auto up and down functions of the power window regulator master switch assembly are operated. Refer to OPERATION CHECK [09/2013 - ]
.
- CHECK WINDOW GLASS SLIDING MOVEMENT (FOR DRIVER SIDE)
- Remove the window regulator.
- Install the window glass onto the door glass run.
- Check if the door window regulator operates smoothly.
- Check that the window glass slides smoothly when sliding it up by hand.
OK
Door window glass slides smoothly.
HINT:
Ensure the following:
- The window glass fits with the glass run without improper contact or deformation.
- Foreign objects are not caught in the glass run.
WARNING:Perform initialization again.
NG → FIT WINDOW GLASS CORRECTLY (REMOVE FOREIGN OBJECTS CAUSING IMPROPER FIT OR REPLACE PARTS)
OK → See step 4
- REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH. Refer to REMOVAL [09/2013 - ]