Jam Protection Function does not Operate [09/2013 - ]: Procedure
- PERFORM INITIALIZATION
- Initialize the front power window regulator motor assembly LH. Refer to INITIALIZATION [09/2013 - ] .
NEXT: Go to next step
- CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP/DOWN FUNCTION)
- Check if the power window auto up and down function operate normally. Refer to OPERATION CHECK [09/2013 - ]
.
OK
Auto up and down function is normal.
NG → See step 4
OK: Go to next step
- Check if the power window auto up and down function operate normally. Refer to OPERATION CHECK [09/2013 - ]
.
- CHECK JAM PROTECTION FUNCTION OPERATING RANGE
- Check if the jam protection function operates normally for the applicable power window.
HINT:
The jam protection function will not operate within 4 mm (0.157 in.) of the fully closed position.
OK
Jam protection function operates normally.
NG → See step 5
OK → END (PROBLEM DUE TO INITIALIZATION FAILURE)
- Check if the jam protection function operates normally for the applicable power window.
- PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [09/2013 - ]
- REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH. Refer to REMOVAL [09/2013 - ]