Service Data [08/2013 - ]
| Battery standard voltage | Positive (+) terminal - Negative (-) terminal | 12.5 to 12.9 V at 20°C (68°F) |
| Generator brush holder assembly (for 100A Type) |
Standard exposed length | 9.5 to 11.5 mm (0.374 to 0.453 in.) |
| Minimum exposed length | 4.5 mm (0.177 in.) | |
| Generator rotor assembly resistance (for 100A Type) |
Slip ring - Slip ring | 1.8 to 2.2 Ω at 20°C (68°F) |
| Slip ring - Rotor | 10 MΩ or higher | |
| Generator rotor assembly slip ring diameter (for 100A Type) |
Standard diameter | 14.2 to 14.8 mm (0.559 to 0.583 in.) |
| Minimum diameter | 14.0 mm (0.551 in.) |