Interior Light Circuit [08/2014 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- PERFORM ACTIVE TEST USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Main Body / Active Test.
- Check that the lights operate.MAIN BODY
Tester Display Test Part Control Range Diagnostic Note Illuminated Entry System Interior lights ON/OFF Interior light door switch on and all doors closed OK
Each light fades in.
NG → See step 2
OK → See step 5
- CHECK HARNESS AND CONNECTOR (BATTERY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
- Disconnect the 2A instrument panel junction block assembly connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition 2A-52 - Body ground Always 11 to 14 V TEXT IN ILLUSTRATION*1 Front view of wire harness connector
(to Instrument Panel Junction Block Assembly)
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- Disconnect the 2A instrument panel junction block assembly connector.
- INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
- Remove the instrument panel junction block assembly.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 2A-52 - A-1 (ILE) Always Below 1 Ω A-1 (ILE) - Body ground Always 10 kΩ or higher TEXT IN ILLUSTRATION*1 Component without harness connected
(Instrument Panel Junction Block Assembly)
NG → REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
OK → See step 4
- Remove the instrument panel junction block assembly.
- REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU). Refer to COMPONENTS [08/2014 - ]
- PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [08/2014 - ]