DTC P0116: Engine Coolant Temperature Circuit Range / Performance Problem [08/2014 - ]: Procedure
- CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P0116)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
- Read the DTCs.
Result
Result Proceed to DTC P0116 is output A DTC P0116 and other DTCs are output B HINT:
If any DTCs other than P0116 are output, troubleshoot those DTCs first.
B → See step 4
A: Go to next step
- INSPECT WATER INLET WITH THERMOSTAT SUB-ASSEMBLY
- Remove the water inlet with thermostat sub-assembly. Refer to REMOVAL [08/2014 - ] .
- Measure the valve opening temperature of the water inlet with thermostat sub-assembly.
Standard value
80 to 84°C (176 to 183°F)
HINT:
- In addition to the above check, confirm that the valve is completely closed when the temperature is below the standard.
- Perform "Inspection After Repair" after replacing the engine coolant temperature sensor. Refer to INITIALIZATION [08/2014 - ] .
NG → See step 5
OK → See step 3
- REPLACE ENGINE COOLANT TEMPERATURE SENSOR. Refer to REMOVAL [08/2014 - ]
- GO TO DTC CHART. Refer to DIAGNOSTIC TROUBLE CODE CHART [08/2014 - ]
- REPLACE WATER INLET WITH THERMOSTAT SUB-ASSEMBLY. Refer to REMOVAL [08/2014 - ]